Entering edit mode
Lizhe Xu
▴
210
@lizhe-xu-666
Last seen 10.2 years ago
Thanks, I did not notice that difference, but how was bioconductor
bgcorrect=MAS method implemented, 10 by 10 or 4 by 4? I did both MAS
with Affy software and MAS in bioconductor on the same data set and
got quite different results. I wonder if the difference comes from the
background correction.
L
Date: Wed, 29 Sep 2004 08:54:03 -0700
From: Ben Bolstad <>
Subject: Re: [BioC] dChip
To: Lizhe Xu <lxu@chnola-research.org>
Cc: hess@stat.colostate.edu, lgautier@altern.org,
bioconductor@stat.math.ethz.ch
Message-ID: <1096473243.3004.3.camel@bmbbox.dyndns.org>
Content-Type: text/plain
Actually I believe that it is a slightly modified version of the MAS
background that is used in dChip. They use a 10 by 10 grid rather than
4
by 4.
Ben