I get the following error when I run arrayQualityMetircs on an
affybatch
file that has 13 Affymetrix CEL files:
Error in .local(object, ...) : subscript out of bounds
The full command is:
arrayQualityMetrics(expressionset = abatch, outdir =
"AQM_GT_Jos5236-5248_Dec_11", force = TRUE, do.logtransform = TRUE)
I also get the following error when running Harshlight on the same
affy
batch file:
Error in indices2xy(i, nr = object at nrow) :
Indices must start at 0 or 1 (please refer to the help file) !
I thought I would add the Harshlight error, because I'll bet the
two
are related. I did not generate the .CEL files. I received them and
put
them into an affy batch file with the command
abatch <- ReadAffy()
Any ideas as to what the problem is ?
Matthew
The information in this e-mail is intended only for the
...{{dropped:11}}
Dear Matthew
Thank you for the report. It is difficult to say what is going on
without more details. In general, please always make sure you are
using
the latest versions of Bioconductor, and include the output of
sessionInfo().
Beyond that, in order to diagnose/fix your problem, we would need an R
script that reproduces the error, and the necessary CEL files (maybe
one
or two already suffice?) or the AffyBatch object.
Best wishes
Wolfgang
On 12/6/11 10:59 PM, Matthew McCormack wrote:
> I get the following error when I run arrayQualityMetircs on an
affybatch
> file that has 13 Affymetrix CEL files:
> Error in .local(object, ...) : subscript out of bounds
>
> The full command is:
> arrayQualityMetrics(expressionset = abatch, outdir =
> "AQM_GT_Jos5236-5248_Dec_11", force = TRUE, do.logtransform = TRUE)
>
> I also get the following error when running Harshlight on the same
affy
> batch file:
> Error in indices2xy(i, nr = object at nrow) :
> Indices must start at 0 or 1 (please refer to the help file) !
>
> I thought I would add the Harshlight error, because I'll bet the two
are
> related. I did not generate the .CEL files. I received them and put
them
> into an affy batch file with the command
> abatch <- ReadAffy()
>
> Any ideas as to what the problem is ?
>
> Matthew
>
>
> The information in this e-mail is intended only for
th...{{dropped:19}}
Hi Wolfgang,
I downloaded the most recent version of arrayQualityMetrics and
everything is working fine now. Thanks for writing this very helpful
package.
Matthew
On 12/6/2011 5:24 PM, Wolfgang Huber wrote:
> Dear Matthew
>
> Thank you for the report. It is difficult to say what is going on
> without more details. In general, please always make sure you are
> using the latest versions of Bioconductor, and include the output of
> sessionInfo().
>
> Beyond that, in order to diagnose/fix your problem, we would need an
R
> script that reproduces the error, and the necessary CEL files (maybe
> one or two already suffice?) or the AffyBatch object.
>
> Best wishes
> Wolfgang
>
>
> On 12/6/11 10:59 PM, Matthew McCormack wrote:
>> I get the following error when I run arrayQualityMetircs on an
affybatch
>> file that has 13 Affymetrix CEL files:
>> Error in .local(object, ...) : subscript out of bounds
>>
>> The full command is:
>> arrayQualityMetrics(expressionset = abatch, outdir =
>> "AQM_GT_Jos5236-5248_Dec_11", force = TRUE, do.logtransform = TRUE)
>>
>> I also get the following error when running Harshlight on the same
affy
>> batch file:
>> Error in indices2xy(i, nr = object at nrow) :
>> Indices must start at 0 or 1 (please refer to the help file) !
>>
>> I thought I would add the Harshlight error, because I'll bet the
two are
>> related. I did not generate the .CEL files. I received them and put
them
>> into an affy batch file with the command
>> abatch <- ReadAffy()
>>
>> Any ideas as to what the problem is ?
>>
>> Matthew
>>
>>
>> The information in this e-mail is intended only for
t...{{dropped:21}}