Entering edit mode
Dear Javier,
oneChannelGUI uses apt tools for intensity summarization. In version
2.4 of Bioconductor gene-level expression
was calculated using HuGene-1_0-st-v1.r3.mps file. In version 2.5 of
Bioconductor it uses
HuGene-1_0-st-v1.r4.mps
Cheers
Raffaele
>Dear list,
>Some time ago I analysed a set of Human Gene ST Arrays with
>oneChannelGUI. Now I'm trying to reproduce the results using oligo
>package but I am quite surprised with the results obtained. With
oligo
>package, after preprocessing with rma, the number of probesets are
>253002 while with oneChannelGUI the number of probesets are 33297,
and
>the CEL files are the same!!!
> truncated
>......
--
----------------------------------------
Prof. Raffaele A. Calogero
Bioinformatics and Genomics Unit
Dipartimento di Scienze Cliniche e Biologiche
c/o Az. Ospedaliera S. Luigi
Regione Gonzole 10, Orbassano
10043 Torino
tel. ++39 0116705417
Lab. ++39 0116705408
Fax ++39 0119038639
Mobile ++39 3333827080
email: raffaele.calogero at unito.it
raffaele[dot]calogero[at]gmail[dot]com
www: http://www.bioinformatica.unito.it
Info: http://publicationslist.org/raffaele.calogero