Analysing Human Gene ST 1.0 Arrays with oligo and, oneChannelGUI yield different number of probesets
0
0
Entering edit mode
rcaloger ▴ 500
@rcaloger-1888
Last seen 9.8 years ago
European Union
Dear Javier, oneChannelGUI uses apt tools for intensity summarization. In version 2.4 of Bioconductor gene-level expression was calculated using HuGene-1_0-st-v1.r3.mps file. In version 2.5 of Bioconductor it uses HuGene-1_0-st-v1.r4.mps Cheers Raffaele >Dear list, >Some time ago I analysed a set of Human Gene ST Arrays with >oneChannelGUI. Now I'm trying to reproduce the results using oligo >package but I am quite surprised with the results obtained. With oligo >package, after preprocessing with rma, the number of probesets are >253002 while with oneChannelGUI the number of probesets are 33297, and >the CEL files are the same!!! > truncated >...... -- ---------------------------------------- Prof. Raffaele A. Calogero Bioinformatics and Genomics Unit Dipartimento di Scienze Cliniche e Biologiche c/o Az. Ospedaliera S. Luigi Regione Gonzole 10, Orbassano 10043 Torino tel. ++39 0116705417 Lab. ++39 0116705408 Fax ++39 0119038639 Mobile ++39 3333827080 email: raffaele.calogero at unito.it raffaele[dot]calogero[at]gmail[dot]com www: http://www.bioinformatica.unito.it Info: http://publicationslist.org/raffaele.calogero
Preprocessing oneChannelGUI Preprocessing oneChannelGUI • 1.2k views
ADD COMMENT

Login before adding your answer.

Traffic: 558 users visited in the last hour
Help About
FAQ
Access RSS
API
Stats

Use of this site constitutes acceptance of our User Agreement and Privacy Policy.

Powered by the version 2.3.6