Entering edit mode
Anjan Purkayastha
▴
90
@anjan-purkayastha-3096
Last seen 10.4 years ago
Hi,
I am trying to use the tilingArray normalization package for the
following array:
total number of probes: 6490. (these are a set of non-overlapping,
contiguous 60mer probes that span the vaccinia virus genome-~200kb)
total number of perfect matches: 6490.
total number of background probes: 1275.( the vaccinia genome is very
densely packed so there are few untranscribed regions).
The above mentioned array is being use to assay the transcription of
the
viral genes over an infection time-course.
Issues:
The probe intensities from DNA-hybs used for normalization are on
average as strong as the non-normalized probe intensities from
transcription assays.
The "normalized" signal after the tilingArray normalization seem to
be
*noisier* than the non-normalized input.
I know there may not be enough material in this email for the Gurus to
provide advice.
I'd be happy to provide more details- genomic map of normalized and
non-normalized signal etc, but there seems to be a size limit to
attachments for this forum.
Please let me know if you have any specific questions regarding the
experiment and/or the data.
All advice/questions will be appreciated.
Anjan
--
===========================================
anjan purkayastha, phd
bioinformatics analyst
whitehead institute for biomedical research
nine cambridge center
cambridge, ma 02142
purkayas [at] wi [dot] mit [dot] edu
703.740.6939